Access to latest Extender data is available by using following URL format:
http://ext.looko2.com/Last/ID_OF_YOUR_EXTENDER
Example: http://ext.looko2.
For Looko2 Extender that is measuring temperature, air pressure and humidity:
{ "Type": 1, Type of sensor "ID": "2CF4324A8C03", Sensor ID "Humidity": 83.56, Humidity % "Pressure": 980.83, Air pressure in hPa values "RelativePressure": 999.14, Relative pressure (sea level) "Altitude": 152, Altitude "Temperature": 1.58, Temperature in C "DewPoint": -0.90, Dew point in C "RSSI": -90, WiFi Signal strength "Epoch": 1576240774, Last seen in EPOCH value "Version": 0.1 Sensor software version }
For Looko2 Extender that is measuring various gases:
{ "Type": 2, Type of sensor "ID": "CC50E3CD9B51", Sensor ID "NH3": 0.19, NH3 PPM "CO": 4.23, CO PPM "NO2": 0.33, NO2 PPM "C4H10": 77.76, C4H10 PPM "CH4": 553.83, CH4 PPM "H2": 0.69, H2 PPM "C2H5OH": 1.55, C2H5OH PPM "RSSI": -61, WiFi Signal strength "Epoch": 1573136025, Last seen in EPOCH value "Version": 0.1 Sensor software version }
For Looko2 Extender measuring CO2:
{ "Type": 3, Type of sensor "ID": "2CF4324A8CB5", Sensor ID "CO2": 406.00, Poziom CO2 PPM "RSSI": -24, WiFi Signal strength "Epoch": 1579274840, Last seen in EPOCH value "Version": 0.1 Sensor software version }