{"id":676,"date":"2020-09-09T17:26:41","date_gmt":"2020-09-09T15:26:41","guid":{"rendered":"https:\/\/looko2web.nazwa.pl\/extender-manual\/"},"modified":"2020-09-16T17:55:47","modified_gmt":"2020-09-16T15:55:47","slug":"extender-manual","status":"publish","type":"post","link":"https:\/\/looko2.pl\/en\/news\/extender-manual\/","title":{"rendered":"Extender manual"},"content":{"rendered":"<p>Thank you for purchasing the looko2 extender with measurement of temperature, air humidity and atmospheric pressure.<\/p>\n<p>Sensor configuration:<\/p>\n<p>1. After connecting the sensor to the network, <strong>wait 2 minutes<\/strong> and search for a WiFi network o<br \/>\nname <strong>LOOKO2E_XXXXXXXX<\/strong> where <strong>XXXXXXXX<\/strong> is the unique number of the Extender<br \/>\n2. After connecting to the above-mentioned network, open a web browser and in<br \/>\nEnter 192.168.4.1 in the address field and press Enter<br \/>\n3. A configuration screen should appear:<\/p>\n<p><img loading=\"lazy\" src=\"https:\/\/looko2web.nazwa.pl\/wp-content\/uploads\/2019\/11\/ext-300x179.png\" alt=\"\" width=\"439\" height=\"262\" class=\"wp-image-453 aligncenter\" srcset=\"https:\/\/looko2.pl\/wp-content\/uploads\/2019\/11\/ext-300x179.png 300w, https:\/\/looko2.pl\/wp-content\/uploads\/2019\/11\/ext.png 670w\" sizes=\"(max-width: 439px) 100vw, 439px\" \/><br \/>\nPlease write down the <strong>Unique ID<\/strong> number: XXXXXXXXX<\/p>\n<p><strong>Select your Access Point (AP)<\/strong> &#8211; please select the WiFi network to which the sensor will be connected<br \/>\n<strong>Provide your AP Password<\/strong> &#8211; please provide the password for the WiFi network<br \/>\n<strong>Provide your Altitude<\/strong> \u2013please enter the altitude above sea level so that the sensor can display corrected pressure values. Leaving this field blank or with a value of zero will cause the sensor to read sea level pressure.<\/p>\n<p>After entering the above-mentioned parameters, please press the <strong>Save button<\/strong><\/p>\n<p>The following message will appear:<\/p>\n<p><strong>Saving &#8230;<\/strong><br \/>\n<strong>Saving OK, rebooting<\/strong><\/p>\n<p>To display sensor data, please use the following format:<\/p>\n<p><strong>http:\/\/ext.looko2.com\/show.php?id=XXXXXXX<\/strong><\/p>\n<p>Where <strong>XXXXXXX<\/strong> is the sensor number that we asked to write down at the beginning of the configuration screen.<\/p>\n<p>The readings will appear up to 5 minutes in the following format:<\/p>\n<p><img loading=\"lazy\" src=\"https:\/\/looko2web.nazwa.pl\/wp-content\/uploads\/2019\/11\/looko2-extender-127x300.png\" alt=\"\" width=\"175\" height=\"413\" class=\" wp-image-457 aligncenter\" srcset=\"https:\/\/looko2.pl\/wp-content\/uploads\/2019\/11\/looko2-extender-127x300.png 127w, https:\/\/looko2.pl\/wp-content\/uploads\/2019\/11\/looko2-extender-433x1024.png 433w, https:\/\/looko2.pl\/wp-content\/uploads\/2019\/11\/looko2-extender.png 518w\" sizes=\"(max-width: 175px) 100vw, 175px\" \/><\/p>\n<p>Resetting the sensors:<br \/>\nIn case you need to reset the WiFi settings of the sensor (e.g. when changing<br \/>\nlocation, connection to another WiFi network, etc.), proceed as follows<br \/>\nprocedure:<\/p>\n<p>1.Prepare the ID of the sensor you are going to reset<\/p>\n<p>2. Disconnect the sensor from the power supply for 30 seconds<\/p>\n<p>3. Connect the sensor to the power supply. From then on, you have 90 seconds to<br \/>\nreset settings. After 90 seconds, the device will go into continuous operation and<br \/>\nit will be necessary to restart the reset procedure from step 1 of this<br \/>\nprocedures<\/p>\n<p>4. Select the WiFi network in the name of which there is the sensor ID that you want to reset<\/p>\n<p>5. After connecting to the above-mentioned WiFi network, open the browser and enter 192.168.4.1\/reset<\/p>\n<p>6. Correctly performed reset of settings will be confirmed by a message<br \/>\nConfig reset completed ok.<\/p>\n<p>7. To reset another sensor, repeat the reset procedure by selecting from the list<br \/>\nanother sensor<\/p>\n<p>8. After a correctly performed reset procedure, wait 90 seconds and you can<br \/>\nproceed to reconfiguring the device.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Thank you for purchasing the looko2 extender with measurement of temperature, air humidity and atmospheric pressure. Sensor configuration: 1. After connecting the sensor to the network, wait 2 minutes and search for a WiFi network o name LOOKO2E_XXXXXXXX where XXXXXXXX is the unique number of the Extender 2. After connecting to the above-mentioned network, open a web browser and in Enter 192.168.4.1 in the address field and press Enter 3. A configuration screen should appear: Please write down the Unique ID number: XXXXXXXXX Select your Access Point (AP) &#8211; please select the WiFi network to which the sensor will be connected Provide your AP Password &#8211; please provide the password for the WiFi network Provide your Altitude \u2013please enter the altitude above sea level so that the sensor can display corrected pressure values. Leaving this field blank or with a value of zero will cause the sensor to read sea level pressure. After entering the above-mentioned parameters, please press the Save button The following message will appear: Saving &#8230; Saving OK, rebooting To display sensor data, please use the following format: http:\/\/ext.looko2.com\/show.php?id=XXXXXXX Where XXXXXXX is the sensor number that we asked to write down at the beginning of the configuration screen. The readings will appear up to 5 minutes in the following format: Resetting the sensors: In case you need to reset the WiFi settings of the sensor (e.g. when changing location, connection to another WiFi network, etc.), proceed as follows procedure: 1.Prepare the ID of the sensor you are going to reset 2. Disconnect the sensor from the power supply for 30 seconds 3. Connect the sensor to the power supply. From then on, you have 90 seconds to reset settings. After 90 seconds, the device will go into continuous operation and it will be necessary to restart the reset procedure from step 1 of this procedures 4. Select the WiFi network in the name of which there is the sensor ID that you want to reset 5. After connecting to the above-mentioned WiFi network, open the browser and enter 192.168.4.1\/reset 6. Correctly performed reset of settings will be confirmed by a message Config reset completed ok. 7. To reset another sensor, repeat the reset procedure by selecting from the list another sensor 8. After a correctly performed reset procedure, wait 90 seconds and you can proceed to reconfiguring the device.<\/p>\n","protected":false},"author":3,"featured_media":710,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[31],"tags":[58],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v18.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/looko2.pl\/en\/news\/extender-manual\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Extender manual - LookO2\" \/>\n<meta property=\"og:description\" content=\"Thank you for purchasing the looko2 extender with measurement of temperature, air humidity and atmospheric pressure. Sensor configuration: 1. After connecting the sensor to the network, wait 2 minutes and search for a WiFi network o name LOOKO2E_XXXXXXXX where XXXXXXXX is the unique number of the Extender 2. After connecting to the above-mentioned network, open a web browser and in Enter 192.168.4.1 in the address field and press Enter 3. A configuration screen should appear: Please write down the Unique ID number: XXXXXXXXX Select your Access Point (AP) &#8211; please select the WiFi network to which the sensor will be connected Provide your AP Password &#8211; please provide the password for the WiFi network Provide your Altitude \u2013please enter the altitude above sea level so that the sensor can display corrected pressure values. Leaving this field blank or with a value of zero will cause the sensor to read sea level pressure. After entering the above-mentioned parameters, please press the Save button The following message will appear: Saving &#8230; Saving OK, rebooting To display sensor data, please use the following format: http:\/\/ext.looko2.com\/show.php?id=XXXXXXX Where XXXXXXX is the sensor number that we asked to write down at the beginning of the configuration screen. The readings will appear up to 5 minutes in the following format: Resetting the sensors: In case you need to reset the WiFi settings of the sensor (e.g. when changing location, connection to another WiFi network, etc.), proceed as follows procedure: 1.Prepare the ID of the sensor you are going to reset 2. Disconnect the sensor from the power supply for 30 seconds 3. Connect the sensor to the power supply. From then on, you have 90 seconds to reset settings. After 90 seconds, the device will go into continuous operation and it will be necessary to restart the reset procedure from step 1 of this procedures 4. Select the WiFi network in the name of which there is the sensor ID that you want to reset 5. After connecting to the above-mentioned WiFi network, open the browser and enter 192.168.4.1\/reset 6. Correctly performed reset of settings will be confirmed by a message Config reset completed ok. 7. To reset another sensor, repeat the reset procedure by selecting from the list another sensor 8. After a correctly performed reset procedure, wait 90 seconds and you can proceed to reconfiguring the device.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/looko2.pl\/en\/news\/extender-manual\/\" \/>\n<meta property=\"og:site_name\" content=\"LookO2\" \/>\n<meta property=\"article:published_time\" content=\"2020-09-09T15:26:41+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-09-16T15:55:47+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/looko2.pl\/wp-content\/uploads\/2020\/09\/extender_looko2.png\" \/>\n\t<meta property=\"og:image:width\" content=\"670\" \/>\n\t<meta property=\"og:image:height\" content=\"400\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"looko2\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/looko2.pl\/en\/#website\",\"url\":\"https:\/\/looko2.pl\/en\/\",\"name\":\"LookO2\",\"description\":\"Tw\u00f3j osobisty czujnik jako\u015bci powietrza (smogu)\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/looko2.pl\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/looko2.pl\/en\/news\/extender-manual\/#primaryimage\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/looko2.pl\/wp-content\/uploads\/2020\/09\/extender_looko2.png\",\"contentUrl\":\"https:\/\/looko2.pl\/wp-content\/uploads\/2020\/09\/extender_looko2.png\",\"width\":670,\"height\":400},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/looko2.pl\/en\/news\/extender-manual\/#webpage\",\"url\":\"https:\/\/looko2.pl\/en\/news\/extender-manual\/\",\"name\":\"Extender manual - LookO2\",\"isPartOf\":{\"@id\":\"https:\/\/looko2.pl\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/looko2.pl\/en\/news\/extender-manual\/#primaryimage\"},\"datePublished\":\"2020-09-09T15:26:41+00:00\",\"dateModified\":\"2020-09-16T15:55:47+00:00\",\"author\":{\"@id\":\"https:\/\/looko2.pl\/en\/#\/schema\/person\/c18e8476e74da065c8bfac73fe46091f\"},\"breadcrumb\":{\"@id\":\"https:\/\/looko2.pl\/en\/news\/extender-manual\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/looko2.pl\/en\/news\/extender-manual\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/looko2.pl\/en\/news\/extender-manual\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Strona g\u0142\u00f3wna\",\"item\":\"https:\/\/looko2.pl\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Extender manual\"}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/looko2.pl\/en\/#\/schema\/person\/c18e8476e74da065c8bfac73fe46091f\",\"name\":\"looko2\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/looko2.pl\/en\/#personlogo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/cc27d56d81e922a45b359d1a4ba0c886?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/cc27d56d81e922a45b359d1a4ba0c886?s=96&d=mm&r=g\",\"caption\":\"looko2\"},\"sameAs\":[\"http:\/\/www.looko2.com\"],\"url\":\"https:\/\/looko2.pl\/en\/author\/looko2\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/looko2.pl\/en\/news\/extender-manual\/","og_locale":"en_US","og_type":"article","og_title":"Extender manual - LookO2","og_description":"Thank you for purchasing the looko2 extender with measurement of temperature, air humidity and atmospheric pressure. Sensor configuration: 1. After connecting the sensor to the network, wait 2 minutes and search for a WiFi network o name LOOKO2E_XXXXXXXX where XXXXXXXX is the unique number of the Extender 2. After connecting to the above-mentioned network, open a web browser and in Enter 192.168.4.1 in the address field and press Enter 3. A configuration screen should appear: Please write down the Unique ID number: XXXXXXXXX Select your Access Point (AP) &#8211; please select the WiFi network to which the sensor will be connected Provide your AP Password &#8211; please provide the password for the WiFi network Provide your Altitude \u2013please enter the altitude above sea level so that the sensor can display corrected pressure values. Leaving this field blank or with a value of zero will cause the sensor to read sea level pressure. After entering the above-mentioned parameters, please press the Save button The following message will appear: Saving &#8230; Saving OK, rebooting To display sensor data, please use the following format: http:\/\/ext.looko2.com\/show.php?id=XXXXXXX Where XXXXXXX is the sensor number that we asked to write down at the beginning of the configuration screen. The readings will appear up to 5 minutes in the following format: Resetting the sensors: In case you need to reset the WiFi settings of the sensor (e.g. when changing location, connection to another WiFi network, etc.), proceed as follows procedure: 1.Prepare the ID of the sensor you are going to reset 2. Disconnect the sensor from the power supply for 30 seconds 3. Connect the sensor to the power supply. From then on, you have 90 seconds to reset settings. After 90 seconds, the device will go into continuous operation and it will be necessary to restart the reset procedure from step 1 of this procedures 4. Select the WiFi network in the name of which there is the sensor ID that you want to reset 5. After connecting to the above-mentioned WiFi network, open the browser and enter 192.168.4.1\/reset 6. Correctly performed reset of settings will be confirmed by a message Config reset completed ok. 7. To reset another sensor, repeat the reset procedure by selecting from the list another sensor 8. After a correctly performed reset procedure, wait 90 seconds and you can proceed to reconfiguring the device.","og_url":"https:\/\/looko2.pl\/en\/news\/extender-manual\/","og_site_name":"LookO2","article_published_time":"2020-09-09T15:26:41+00:00","article_modified_time":"2020-09-16T15:55:47+00:00","og_image":[{"width":670,"height":400,"url":"https:\/\/looko2.pl\/wp-content\/uploads\/2020\/09\/extender_looko2.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Written by":"looko2","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebSite","@id":"https:\/\/looko2.pl\/en\/#website","url":"https:\/\/looko2.pl\/en\/","name":"LookO2","description":"Tw\u00f3j osobisty czujnik jako\u015bci powietrza (smogu)","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/looko2.pl\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"ImageObject","@id":"https:\/\/looko2.pl\/en\/news\/extender-manual\/#primaryimage","inLanguage":"en-US","url":"https:\/\/looko2.pl\/wp-content\/uploads\/2020\/09\/extender_looko2.png","contentUrl":"https:\/\/looko2.pl\/wp-content\/uploads\/2020\/09\/extender_looko2.png","width":670,"height":400},{"@type":"WebPage","@id":"https:\/\/looko2.pl\/en\/news\/extender-manual\/#webpage","url":"https:\/\/looko2.pl\/en\/news\/extender-manual\/","name":"Extender manual - LookO2","isPartOf":{"@id":"https:\/\/looko2.pl\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/looko2.pl\/en\/news\/extender-manual\/#primaryimage"},"datePublished":"2020-09-09T15:26:41+00:00","dateModified":"2020-09-16T15:55:47+00:00","author":{"@id":"https:\/\/looko2.pl\/en\/#\/schema\/person\/c18e8476e74da065c8bfac73fe46091f"},"breadcrumb":{"@id":"https:\/\/looko2.pl\/en\/news\/extender-manual\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/looko2.pl\/en\/news\/extender-manual\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/looko2.pl\/en\/news\/extender-manual\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Strona g\u0142\u00f3wna","item":"https:\/\/looko2.pl\/en\/"},{"@type":"ListItem","position":2,"name":"Extender manual"}]},{"@type":"Person","@id":"https:\/\/looko2.pl\/en\/#\/schema\/person\/c18e8476e74da065c8bfac73fe46091f","name":"looko2","image":{"@type":"ImageObject","@id":"https:\/\/looko2.pl\/en\/#personlogo","inLanguage":"en-US","url":"https:\/\/secure.gravatar.com\/avatar\/cc27d56d81e922a45b359d1a4ba0c886?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/cc27d56d81e922a45b359d1a4ba0c886?s=96&d=mm&r=g","caption":"looko2"},"sameAs":["http:\/\/www.looko2.com"],"url":"https:\/\/looko2.pl\/en\/author\/looko2\/"}]}},"_links":{"self":[{"href":"https:\/\/looko2.pl\/en\/wp-json\/wp\/v2\/posts\/676"}],"collection":[{"href":"https:\/\/looko2.pl\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/looko2.pl\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/looko2.pl\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/looko2.pl\/en\/wp-json\/wp\/v2\/comments?post=676"}],"version-history":[{"count":1,"href":"https:\/\/looko2.pl\/en\/wp-json\/wp\/v2\/posts\/676\/revisions"}],"predecessor-version":[{"id":704,"href":"https:\/\/looko2.pl\/en\/wp-json\/wp\/v2\/posts\/676\/revisions\/704"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/looko2.pl\/en\/wp-json\/wp\/v2\/media\/710"}],"wp:attachment":[{"href":"https:\/\/looko2.pl\/en\/wp-json\/wp\/v2\/media?parent=676"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/looko2.pl\/en\/wp-json\/wp\/v2\/categories?post=676"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/looko2.pl\/en\/wp-json\/wp\/v2\/tags?post=676"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}